Apc Br1500gi Back Ups Black One Size / EU Plug 220V. The APC Back-UPS Pro 1500 provides premium power protection for your computers and electronics. It offers battery and surge-protected outlets, along with surge-only outlets for less critical devices. Features like Automatic Voltage Regulation (AVR), adjustable voltage sensitivity, and a Green Mode ensure optimal power delivery and energy efficiency. The unit includes an LCD display for easy monitoring, audible alarms, and user-replaceable, hot-swappable batteries for uninterrupted operation and quick maintenance. Dataline surge protection safeguards your connections. EU PLUG.Features:- Apc Power-Saving Back-Ups Pro 1500, 230v.- High Performance Computer And Electronics Ups For Premium Power Protection.- Includes:Cd With Software, Qty 1- Detachable Iec Power Cord, Telephone Cable, Usb Cable, User Manual Adjustable Voltage Sensitivity:- Provides The Ability To Adapt The Ups For Optimal Performance In Specific Power Environments Or Generator Applications.Adjustable Voltage-Transfer Points:- Maximizes Useful Battery Life By Widening The Input Voltage Window Or Tightening The Output Voltage Regulation.- Audible Alarms:Provides Notification Of Changing Utility Power And Ups Power Conditions.- Automatic Self-Test:Periodic Battery Self-Test Ensures Early Detection Of A Battery That Needs To Be Replaced.- Battery Failure Notification:Provides Early-Warning Fault Analysis On Batteries Enabling Timely Preventive Maintenance.- Battery Replacement Without Tools:Enables Fast Battery Replacement, Lowering Mean Time To Repair (Mttr).Battery-Protected And Surge-Only Outlets:- Reserves Power Capacity And Run Time For Connected Equipment That Require Ups Battery Back-Up While Providing Surge Only Protection For Less Critical Equipment Boost And Trim Automatic Voltage Regulation (Avr):- Gives Higher Application Availability By Correcting Low And High Voltage Conditions Without Using The Battery (Not Available On All Models).- Building Wiring Fault Indicator:This Led Informs Users Of Potentially Dangerous Wiring Problems In The Wall Circuit.- Cold-Start Capable:Provides Temporary Battery Power When The Utility Power Is Out.- Dataline Surge Protection:Provides Protection Of Connected Equipment From Power Surges On The Data Lines.- Disconnected Battery Notification:Warns When A Battery Is Not Available To Provide Backup Power.Extendable Run Time:- Additional Batteries Can Be Added To Provide Power To The Load For An Extended Period Of Time In The Event Of Utility Supply Failure.Green Mode:- Patent-Pending Operating Mode That Bypasses Unused Electrical Components In Good Power Conditions To Achieve Very High Operating Efficiency Without Sacrificing Any Protection.- Hot-Swappable Batteries:Ensures Clean, Uninterrupted Power To Protected Equipment While Batteries Are Being Replaced.- Intelligent Battery Management:Maximizes Battery Performance, Life, And Reliability Through Intelligent, Precision Charging.- Lcd Graphics Display:Text And Mimic Diagrams That Display Modes Of Operation, System Parameters And Alarms.- Power-Saving Outlets:Automatically Cuts Power To Idle Equipment To Conserve Electricity.- Resettable Circuit Breaker:Easy Recovery From Overloads.No Need To Replace A Fuse.(Not Available On Wall Tap Skus) Safety-Agency Approved:- Ensures The Product Has Been Tested And Approved To Work Safely With The Connected Service Provider Equipment And Within The Specified Environment.- Serial Connectivity:Provides Management Of The Ups Via A Serial Port.- Telephone Dataline Surge Protection:Provides Protection Of Connected Equipment From Power Surges Traveling On Telephone Lines.- Transformer-Block Spaced Outlets:Protect Equipment With Input Transformer Blocks Without Blocking Access To Other Receptacles.- Usb Connectivity:Provides Management Of The Ups Via A Usb Port (Not Available On All Models).User-Replaceable Batteries:- Increases Availability By Allowing A Trained User To Perform Upgrades And Replacements Of The Batteries Reducing Mean Time To Repair (Mttr) Protection:- Battery And Surge Protected Outlets:Back Up And Protect Your Hardware And Data During Power Outages, Surges And Spikes.- Dataline Surge Protection:Provides Protection Of Connected Equipment From Power Surges On The Data Lines.Surge Only Outlets:- Protect Secondary Electronics From Surges And Spikes Without Reducing Battery Power Used To Run Primary Electronics During An Outage.Serviceability:- Simple Battery Replacement:Increases Ups Availability By Allowing Quick, Easy Battery Replacement.- Resettable Circuit Breaker:Easy Recovery From Overloads.No Need To Replace A Fuse.(Not Available On Wall Tap Skus) Manageability:- Lcd Status Display:Provides Key Ups Status At A Glance.Multiple Status Indicators With Load And Battery Bar Graphs.- Usb Connection:Use Your Pc To Access Additional Power Protection And Management Features For Your Ups Via A Usb Port.- Disconnected Battery Notification:Warns When A Battery Is Not Available To Provide Backup Power.- Audible Alarms:Provides Notification Of Changing Utility Power And Ups Power Conditions Battery-Protected And Surge-Only Outlets:- Reserves Power Capacity And Run Time For Connected Equipment That Require Ups Battery Back-Up While Providing Surge Only Protection For Less Critical Equipment Green Mode:- Patent-Pending Operating Mode That Bypasses Unused Electrical Components In Good Power Conditions To Achieve Very High Operating Efficiency Without Sacrificing Any Protection.Lcd Status Display:- Provides Key Ups Status At A Glance.Multiple Status Indicators With Load And Battery Bar Graphs.Boost Automatic Voltage Regulation (Avr):- Preserves Battery Life And Maximizes Runtime By Correcting Low Voltages Without Discharging The Battery.Safety:Safety-Agency Approved:- Ensures The Product Has Been Tested And Approved To Work Safely With The Connected Service Provider Equipment And Within The Specified Environment.Availability:- Transformer-Block Spaced Outlets:Protect Equipment With Input Transformer Blocks Without Blocking Access To Other Receptacles.- Automatic Self-Test:Periodic Battery Self-Test Ensures Early Detection Of A Battery That Needs To Be Replaced.- Battery Failure Notification:Provides Early-Warning Fault Analysis On Batteries Enabling Timely Preventive Maintenance.- Cold-Start Capable:Provides Temporary Battery Power When The Utility Power Is Out.- Intelligent Battery Management:Maximizes Battery Performance, Life, And Reliability Through Intelligent, Precision Charging.Customizable Voltage Sensitivity:- Toggle Between Pre-Determined Voltage-Transfer Points Depending On Your Power Quality (High, Medium Or Low Sensitivity), Maximizing Useful Battery Life And Protecting Sensitive Electronics.Customizable Voltage-Transfer Points:- Adjust The Voltage Points (Widen Or Tighten The Range) Where Your Ups Transfers To Battery To Maximize Useful Battery Life And Protect Sensitive Electronics.Green Mode:- Patent-Pending Operating Mode That Bypasses Unused Electrical Components In Good Power Conditions To Achieve Very High Operating Efficiency Without Sacrificing Any Protection.Boost And Trim Automatic Voltage Regulation (Avr):- Gives Higher Application Availability By Correcting Low And High Voltage Conditions Without Using The Battery (Not Available On All Models).Specifications:Output:- Output Power Capacity:865watts / 1.5kva.- Max Configurable Power (Watts):865watts / 1.5kva.- Nominal Output Voltage:230v.- Output Frequency (Sync To Mains):50/60hz +/- 3 Hz.- Load Crest Factor:3:1.- Topology:Line Interactive.- Waveform Type:Stepped Approximation To A Sinewave Output Connections:- Iec 320 C13 (Battery Backup).- Iec Jumpers (Battery Backup).- Iec 320 C13 (Surge Protection) Transfer Time:- 10ms Typical:12ms Maximum Input:- Nominal Input Voltage:230v.- Input Frequency:50/60 Hz +/- 3 Hz (Auto Sensing).- Input Connections:Iec-320 C14.- Input Voltage Range For Main Operations:176.- 294v.- Input Voltage Adjustable Range For Mains Operation:156.- 300v.- Number Of Power Cords:1 Batteries:- Battery Type:Maintenance-Free Sealed Lead-Acid Battery With Suspended Electrolyte:Leakproof.- Typical Recharge Time:8hour(S).- Battery Volt-Amp-Hour Capacity:187 Communications & Management:- Interface Port(S):Optional Simple Signalling Rs232 Cable, Usb.- Control Panel:Multi-Function Lcd Status And Control Console.- Audible Alarm:Alarm When On Battery:Distinctive Low Battery Alarm:Overload Continuous Tone Alarm Surge Protection And Filtering:- Surge Energy Rating:441joules Data Line Protection:- Analog Phone Line For Phone/Fax/Modem/Dsl (Rj-11 Connector), Network Line.- 10/100/1000 Base-T Ethernet (Rj-45 Connector).- Filtering:Full Time Multi-Pole Noise Filtering:10% Of Ieee Surge Let-Thgouh:Zero Clamping Response Time:Instantaneous Physical:- Maximum Height:301mm, 30.1cm.- Maximum Width:112mm, 11.2cm.- Maximum Depth:380mm, 38.0cm.- Net Weight:12.7kg.- Shipping Weight:14.3kg.- Shipping Height:387mm, 38.7cm.- Shipping Width:238mm, 23.8cm.- Shipping Depth:488mm, 48.8cm.- Master Carton Units:1.0.- Units Per Pallet:20.0 Environmental:- Operating Temperature:0.- 40 °C.- Operating Relative Humidity:0.- 95 %.- Operating Elevation:0-9000meters.- Storage Temperature:-15.- 45 °C.- Storage Relative Humidity:0.- 95 %.- Storage Elevation:0-15000meters.- Audible Noise At 1 Meter From Surface Of Unit:45.0dba Conformance:- Approvals:A-Tick, C-Tick, Ce, Gost, Gs Mark, Telepermit, Tuv.- Equipment Protection Policy:Lifetime:200000 Aud, Lifetime:150000 Euros, Lifetime:75000 Gbp. tradeinn Techinn
Product specifications
| Brand | APC |
|---|---|
| EAN |
|
| Color |
|
| Size |
|
| Gender |
|
| MPN |
|
Price History
Prices were last updated on: