Martindale EasyPAT 2100 PAT Tester

Prices from
1,053.00

Sponsored links

COMPARE ALL WEBSHOPS (3)

Description

test-meter.co.uk #html-body [data-pb-style=BCV3MJW]{justify-content:flex-start;display:flex;flex-direction:column;background-position:left top;background-size:cover;background-repeat:no-repeat;background-attachment:scroll;border-style:none;border-width:1px;border-radius:0;margin:0 0 10px;padding:10px}#html-body [data-pb-style=OKHDBOU]{border-style:none;border-width:1px;border-radius:0;margin:0;padding:0}#html-body [data-pb-style=GH3LQJX]{justify-content:flex-start;display:flex;flex-direction:column;background-position:left top;background-size:cover;background-repeat:no-repeat;background-attachment:scroll;margin:0 0 10px;padding:10px}Martindale EasyPAT 2100 Dual Voltage PAT Tester with Flash Test The Martindale EasyPAT 2100 is a professional dual-voltage manual PAT tester designed for comprehensive electrical safety testing of 110V and 230V portable appliances. It combines straightforward push-button operation with a broader range of tests than the EasyPAT 1600, including run current, run leakage and flash testing. Suitable for Class I and Class II appliances, the EasyPAT 2100 provides selectable 200mA, 8A and 25A earth continuity testing. The low-current 200mA setting is particularly useful when testing sensitive IT equipment, while the 8A and 25A options provide high-current earth bond testing where required. A 500V DC insulation resistance test is provided alongside run current testing up to 16A and run leakage measurement up to 19.9mA. The EPAT2100 also incorporates flash testing at 1.5kV AC for Class I appliances and 3kV AC for Class II appliances, making it suitable for users who require a wider range of appliance safety tests. The tester can be powered from either a 110V or 230V supply and provides dedicated sockets for testing both 110V and 230V appliances. A built-in lead test function also allows IEC leads and extension leads to be checked, with the supplied adaptors simplifying testing across different appliance types. Designed for electricians, maintenance engineers, workshops and professional PAT testing applications, the EasyPAT 2100 combines comprehensive manual testing capability with a simple interface, avoiding complicated menus or data-management functions.Martindale EasyPAT 1600 vs EasyPAT 2100 Both EasyPAT models provide manual testing of 110V and 230V appliances, but the EPAT2100 adds run current, run leakage and flash testing for users requiring a broader range of PAT functions. Feature Martindale EasyPAT 1600 Martindale EasyPAT 2100 Class I & Class II Testing Yes Yes 110V & 230V Appliance Testing Yes Yes Earth Continuity Test 200mA, 8A & 25A 200mA, 8A & 25A Insulation Test 500V DC 500V DC IEC / Extension Lead Testing Yes Yes Fuse Test Yes Via Run Test Run Current Test No Yes Run Leakage Test No Yes Flash Testing No 1.5kV Class I / 3kV Class II Results Memory / Download No No Tester Supply 230V mains 110V / 230V mains Best Suited To Straightforward manual PAT testing More comprehensive PAT testing including run, leakage and flash tests

Compare webshops (3)

Sponsored links · Some shops pay us a fee

Sort by:

£ 1,053.00

£ 1,053.00

£ 1,074.00

Description (2)
Test-meter.co.uk

#html-body [data-pb-style=BCV3MJW]{justify-content:flex-start;display:flex;flex-direction:column;background-position:left top;background-size:cover;background-repeat:no-repeat;background-attachment:scroll;border-style:none;border-width:1px;border-radius:0;margin:0 0 10px;padding:10px}#html-body [data-pb-style=OKHDBOU]{border-style:none;border-width:1px;border-radius:0;margin:0;padding:0}#html-body [data-pb-style=GH3LQJX]{justify-content:flex-start;display:flex;flex-direction:column;background-position:left top;background-size:cover;background-repeat:no-repeat;background-attachment:scroll;margin:0 0 10px;padding:10px}Martindale EasyPAT 2100 Dual Voltage PAT Tester with Flash Test The Martindale EasyPAT 2100 is a professional dual-voltage manual PAT tester designed for comprehensive electrical safety testing of 110V and 230V portable appliances. It combines straightforward push-button operation with a broader range of tests than the EasyPAT 1600, including run current, run leakage and flash testing. Suitable for Class I and Class II appliances, the EasyPAT 2100 provides selectable 200mA, 8A and 25A earth continuity testing. The low-current 200mA setting is particularly useful when testing sensitive IT equipment, while the 8A and 25A options provide high-current earth bond testing where required. A 500V DC insulation resistance test is provided alongside run current testing up to 16A and run leakage measurement up to 19.9mA. The EPAT2100 also incorporates flash testing at 1.5kV AC for Class I appliances and 3kV AC for Class II appliances, making it suitable for users who require a wider range of appliance safety tests. The tester can be powered from either a 110V or 230V supply and provides dedicated sockets for testing both 110V and 230V appliances. A built-in lead test function also allows IEC leads and extension leads to be checked, with the supplied adaptors simplifying testing across different appliance types. Designed for electricians, maintenance engineers, workshops and professional PAT testing applications, the EasyPAT 2100 combines comprehensive manual testing capability with a simple interface, avoiding complicated menus or data-management functions.Martindale EasyPAT 1600 vs EasyPAT 2100 Both EasyPAT models provide manual testing of 110V and 230V appliances, but the EPAT2100 adds run current, run leakage and flash testing for users requiring a broader range of PAT functions. Feature Martindale EasyPAT 1600 Martindale EasyPAT 2100 Class I & Class II Testing Yes Yes 110V & 230V Appliance Testing Yes Yes Earth Continuity Test 200mA, 8A & 25A 200mA, 8A & 25A Insulation Test 500V DC 500V DC IEC / Extension Lead Testing Yes Yes Fuse Test Yes Via Run Test Run Current Test No Yes Run Leakage Test No Yes Flash Testing No 1.5kV Class I / 3kV Class II Results Memory / Download No No Tester Supply 230V mains 110V / 230V mains Best Suited To Straightforward manual PAT testing More comprehensive PAT testing including run, leakage and flash tests

Amazon

Tests 110V & 240V appliances Class I, Class II & Lead Test High & low current earth bond tests at 8A, 25A, and 200mA IT safe Run current & leakage test Hipot / Flash test for tool hire and workshop service & repair testing


Product specifications

Brand Martindale
EAN
  • 5036162184482
MPN
  • Epat2100
  • MAREPAT2100


Price History

* Price history contains no data from Amazon, Amazon Marketplace.

Prices were last updated on:

Featured Choice
£ 1,053.00
To Shop