VANDAGRAPH 9730210 Quick Ox Sampler for Adults, Designed Everyday use

Prices from
25.49

Sponsored links

COMPARE ALL WEBSHOPS (3)

Description

DiveInn Vandagraph Quick-ox Sampler. Accurately measure oxygen in your dive tanks with the VANDAGRAPH Quick-OX Sampler. Designed for nitrox and mixed gas divers, it provides fast, precise readings (+/- 1% accuracy) by eliminating issues like flow rate resistance, temperature sensitivity, and Venturi air dilution. The innovative dome design creates a stable, low-pressure sample stream, funneling gas directly into your sensor while preventing backflow and minimizing gas loss. Easy to use for all diver levels, it requires minimal skill for accurate calibration. The Quick-Ox was designed because of a need to measure accurately, easily and quickly the oxygen concentration in a sub-aqua diving cylinder. Nitrox and mixed gas diving requires accurate mixing and measurement. Accuracy must be better than +/- 1%. With a preferable resolution of +/- 0.1% (Sensor not included).Features and Benefits:Effects of flow rate:- As most Oxygen sensors are partial pressure measuring devices the high flow rates meeting a resistance translate- into pressure give a false high reading. The sensor will work with a flow rate between 100 millitres per minute to 2- litres per minute. This has normally been achieved by the use of a flow meter or flow reducer/restrictor. As Oxygen- Has a partial pressure of .209 Bar at STP, which the electronic measuring device translates to 20.9%, the most- Accurate pressure to take a measurement is therefore also at 1Bar. Effects of Temperature:- When the cylinder is opened the gas pressure is reducing from 200+ Bar to 1 Bar atmospheric. This causes a severedrop in temperature of the gas. The sensors are very temperature sensitive (2.5% per degree Celsius change) sotemperature compensation is required. This is usually fitted externally on the rear of the sensor. However, atemperature gradient is created where the sensor temperature compensation mechanism is fed information from roomtemperature and the sensor gas sensing membrane is experiencing low and dropping temperatures.This exhibits itself as a varying baseline. Venturi action:- The diver using the device usually wants to take a measurement quickly and ideally directly from the outlet valve ofthe cylinder.- Most devices that enable this also have the problem of a possible Venturi effect of drawing in room air during- Measurement and diluting the measured gas. How does it work:- The Dome is designed to fit flush against the O ring on a Scuba cylinder and also fit into the thread of a Scuba DINfitting.- The Dome has been fitted with a concave inlet and a small hole at the end so that the gas builds up in the concaveand forces the room air to out of the sampling gas stream The hole size has been chosen to restrict the flow yet allow- Sufficient gas to enter the sensor and enable the fast response. Venturi effects are eliminated.- The gas stream is funnelled by the concave on the dome through the hole and then through a one-way valve so thatthe gas goes in but cannot return back through the dome.- Excess high pressure gas travels directly through the Tee and out into the atmosphere.Some of the gas is deflected into the sensor by the flow divertor.- When a maximum reading is reached the gas flow is turned off and the gas is trapped at 1Bar in the sensor by asecond one-way valve on the outlet.- The one-way valves on the outlet also serves to stop air re-entering the sensor during the reading period.Advantages:- The Quick-Ox offers fast accurate measurement with minimum loss of gas and minimum skill.- A by product of this system is the gas flows across the sensor. This prevents high pressures, which can damage themembrane of the sensor and not directly onto the sensor face as in existing Dome sensing system.- This device can be used by any level of diver and is not dependent on skill to achieve accuracy. Calibration is easy- And fast by removing the flow divertor and waving in fresh air. . tradeinn Diveinn

Compare webshops (3)

Sponsored links · Some shops pay us a fee

Sort by:

£ 25.49

£ 36.99

£ 36.99

Description (2)
DiveInn

Vandagraph Quick-ox Sampler. Accurately measure oxygen in your dive tanks with the VANDAGRAPH Quick-OX Sampler. Designed for nitrox and mixed gas divers, it provides fast, precise readings (+/- 1% accuracy) by eliminating issues like flow rate resistance, temperature sensitivity, and Venturi air dilution. The innovative dome design creates a stable, low-pressure sample stream, funneling gas directly into your sensor while preventing backflow and minimizing gas loss. Easy to use for all diver levels, it requires minimal skill for accurate calibration. The Quick-Ox was designed because of a need to measure accurately, easily and quickly the oxygen concentration in a sub-aqua diving cylinder. Nitrox and mixed gas diving requires accurate mixing and measurement. Accuracy must be better than +/- 1%. With a preferable resolution of +/- 0.1% (Sensor not included).Features and Benefits:Effects of flow rate:- As most Oxygen sensors are partial pressure measuring devices the high flow rates meeting a resistance translate- into pressure give a false high reading. The sensor will work with a flow rate between 100 millitres per minute to 2- litres per minute. This has normally been achieved by the use of a flow meter or flow reducer/restrictor. As Oxygen- Has a partial pressure of .209 Bar at STP, which the electronic measuring device translates to 20.9%, the most- Accurate pressure to take a measurement is therefore also at 1Bar. Effects of Temperature:- When the cylinder is opened the gas pressure is reducing from 200+ Bar to 1 Bar atmospheric. This causes a severedrop in temperature of the gas. The sensors are very temperature sensitive (2.5% per degree Celsius change) sotemperature compensation is required. This is usually fitted externally on the rear of the sensor. However, atemperature gradient is created where the sensor temperature compensation mechanism is fed information from roomtemperature and the sensor gas sensing membrane is experiencing low and dropping temperatures.This exhibits itself as a varying baseline. Venturi action:- The diver using the device usually wants to take a measurement quickly and ideally directly from the outlet valve ofthe cylinder.- Most devices that enable this also have the problem of a possible Venturi effect of drawing in room air during- Measurement and diluting the measured gas. How does it work:- The Dome is designed to fit flush against the O ring on a Scuba cylinder and also fit into the thread of a Scuba DINfitting.- The Dome has been fitted with a concave inlet and a small hole at the end so that the gas builds up in the concaveand forces the room air to out of the sampling gas stream The hole size has been chosen to restrict the flow yet allow- Sufficient gas to enter the sensor and enable the fast response. Venturi effects are eliminated.- The gas stream is funnelled by the concave on the dome through the hole and then through a one-way valve so thatthe gas goes in but cannot return back through the dome.- Excess high pressure gas travels directly through the Tee and out into the atmosphere.Some of the gas is deflected into the sensor by the flow divertor.- When a maximum reading is reached the gas flow is turned off and the gas is trapped at 1Bar in the sensor by asecond one-way valve on the outlet.- The one-way valves on the outlet also serves to stop air re-entering the sensor during the reading period.Advantages:- The Quick-Ox offers fast accurate measurement with minimum loss of gas and minimum skill.- A by product of this system is the gas flows across the sensor. This prevents high pressures, which can damage themembrane of the sensor and not directly onto the sensor face as in existing Dome sensing system.- This device can be used by any level of diver and is not dependent on skill to achieve accuracy. Calibration is easy- And fast by removing the flow divertor and waving in fresh air. . tradeinn Diveinn

Amazon

VANDAGRAPH makes this quick ox sampler a natural fit for everyday tasks at home, at work or on the move, offering a clear, comfortable fit from the first use. Made to support home users, professionals and anyone who values practical results, because it supports confident work where comfort, pace and control make a difference. A key advantage is thoughtful design and comfortable handling, creating a dependable feel that supports cleaner results and pleasant handling. Where consistency matters, it is designed to reduce effort and keep results consistent, so the job moves forward with fewer interruptions. It also keeps a natural and convincing. Added to your kit, it provides long-lasting usefulness you will appreciate again and again, making it a sensible choice for frequent routines and long-term buying confidence.


Product specifications

Brand Vandagraph
EAN
  • 0637913303838
Color
  • White
Size
  • One Size
Gender
  • Unisex
MPN
  • 9730210


Price History

* Price history contains no data from Amazon, Amazon Marketplace.

Prices were last updated on:

Featured Choice
£ 25.49
To Shop